Product Description
WHY MAHINDRA POWEROL GENERATORS
- Lowest Fuel Consumption in its class.
- Better Block load Capacity.
- Strong service team with factory trained service engineers and dealer network all over Nepal.
- High power to weight ratio.
- More than 800 nos. satisfied customer base in Nepal.
- Mahindra is manufacturer of both engine as well as gensets, Whereas others are Genset assemblers.
- Factory tested gensets of better Quality as first engine is tested while assembly, then after Genset assembly.
- ALL bought outs are from reputed international manufacturers like , Mico / Bosch – Fuel pump , Crompton Greaves/Leroy Somers – Alternators, Deep Sea Controller etc
ENGINE FEATURES & BENEFITS
- Low basic engine noise level.
- Contributes to bettering the statutory MoEF stipulated noise level of 75 dB(A) for the DG set.
- Lowest exhaust emissions. Meet the next generation CPCB-II and US Tier-2 norms.
- Modular design. High degree of commonality of hardware and components over entire range.
- East accessibility of maintenance parts.
- Extended period between overhauls and hassle-free operation especially at high ambient temperatures commonly seen across the Indian sub-continent. Operates efficiently at temperatures from -20°C to 50°C.
MAHINDRA POWEROL Generators PHILOSOPHY
- To deal in quality products of international standards.
- To form a broad customer base by achieving customer satisfaction through quality pre-sales and after-sales services.
- To assure ours & our principal’s growth through consistent and innovative marketing efforts
MAHINDRA GENSET HISTORY
Mahindra & Mahindra Ltd. Entered the field of power generation in 2002. The company is engaged in manufacturing of diesel engines, generating sets. The company owns two manufacturing units located in the Pune, Chennai (Tamil Nadu) and Delhi and 160 service points across India offer 24–7 support to most key markets. Mahindra Powerol is present in countries across Latin America, Africa, the Middle East, and Southeast Asia—and expanding into the United Arab Emirates, Bangladesh, and Nepal. more than 150,000 Mahindra Powerol engines and diesel generator sets (gensets) have been installed in India, offering standard proper quality power.
NEW GENERATION POWER SOLUTIONS
Mahindra & Mahindra Limited is one of the leading companies in India with core competencies in Engines and Generating sets in response to growing demands for increased electric power in India. The company is now poised to set new benchmarks of growth with emphasis on customer satisfaction, technology and human resource
MAHINDRA POWEROL TARGETED MARKET
- NGO’s & INGO’s
- Banks / Co-Operatives / Financial Institutes
- School/ Colleges / Institutes E.g. Educational, Computer etc
- Departmental Stores
- Corporate Houses
- Hydro Power
- Airports
- Industries
- Government and Private Organization
- Clinic’s and Hospitals
- Contractors
- Hotels and Restaurants
- Residence / Housing Apartments
- Workshop
- Dairy / Textiles / Garments
MAHINDRA PRODUCT RANGE
SERIES |
ENGINE MODEL |
ALTERNATOR |
RATING (KVA) |
RATING (KW)
PF(0.8) |
PHASE |
MDI
(Mahindra Direct Injection) |
2185GM |
CROMPTON GREAVES |
10 |
8 |
1/3 |
2185GM |
CROMPTON GREAVES |
12.5 |
10 |
1/3 |
3255GM |
CROMPTON GREAVES |
15 |
12 |
1/3 |
3305GM |
CROMPTON GREAVES |
20 |
16 |
1/3 |
3385 TCIGM/4375 GM |
CROMPTON GREAVES |
25 |
20 |
1/3 |
4445 TC GM |
CROMPTON GREAVES |
30 |
24 |
1/3 |
4575 TCI GM |
CROMPTON GREAVES |
40 |
32 |
3 |
NEF
(New Engine Family) |
4725 GM |
CROMPTON GREAVES |
50 |
40 |
3 |
4.12 TC |
CROMPTON GREAVES |
62.5 |
50 |
3 |
4130 TCIGM |
CROMPTON GREAVES |
75 |
60 |
3 |
MHEPL
(Mahindra Heavy Engine Private Limited) |
4.12 TCA |
CROMPTON GREAVES |
82.5 |
66 |
3 |
4.12 TCA |
CROMPTON GREAVES |
100 |
80 |
3 |
6.12 TCA |
CROMPTON GREAVES |
125 |
100 |
3 |
6.12 TCA |
CROMPTON GREAVES |
140 |
112 |
3 |
6.12 TCA |
CROMPTON GREAVES |
160 |
128 |
3 |
|
CROMPTON GREAVES |
180 |
144 |
3 |
6.12 TCE |
CROMPTON GREAVES |
200 |
160 |
3 |
ADVANTAGES
- Fuel efficient engines running on Diesel Efficiency Technology.
- Robust engine with proven performance ensuring reliability & longer product life.
- Better weight to power ratio resulting in compact engine size.
- Low cost of ownership.
- Less vibrations & low sound levels.
- Ready availability of spare parts.
- Effective after sales service Nationwide.
- 100% testing of units manufactured at Mahindra Powerol.
- Aesthetically superior, low foot print, high quality sound enclosures providing optimum cooling for engine & alternator.
- Diesel engine & Diesel Generator control system at par in its class.
- Low lube oil consumption.
- Certified CPCB II Standard.
- Thick sheet gauge
FEATURES
- Adequate visual indications provided for enhanced worker safety.
- Fire retardant foam and inside heat resistant. Rockwool insulation for better sound attenuation.
- Residential Silencer placed inside hot chamber area within enclosure for further noise reduction. Hot chamber area isolated from rest of generator components which improves the working life of components.
- Top air discharge provision for better sound reduction.
- Remote monitoring options available.
- Diesel fill cap located inside enclosure to prevent diesel theft.
- Multi-Window Product support encompassing Sales, Spare Parts, Service & AMC.
- DG Sets built by Engine Manufacturer.
- DG Sets are complying with CPCB-II Norms.
- DG Sets are compact in size which saves space and light weight as compared to other Manufacturers.
POWER FACTOR
- Power Factor of DG set in single phase is 1 whereas in Three phase is 0.8
- Unity Power Factor- lighting, heating, rectifier.
- Lagging Power Factor- part and starting load of induction motor.
- Leading Power Factor- capacitor load
SERVICE BACK UP
- 24 months warranty.
- Door to door service.
- 24 x 7 services available.
- Genuine spares availability.
- Trained service engineers.
WHAT IS CPCB II
CPCB-II is the next level of emission norms after CPCB I mandating significant reduction in engine exhaust emissions for diesel generators up-to 800 kW in India. CPCB is an acronym known industry-wide (Central Pollution Control Board) for proposed changes/revisions in prevailing emission and noise rules for genset applications.